TECHNICAL DATA – series HV155

  • VDR interference suppression on the collector
  • Direction of rotation depending on polarity
  • Can be mounted in any position
  • Maximum radial shaft load: 10N
  • Maximum axial shaft load: 5N
  • Temperature range: -20 °C/60 °C
  • Approx weight: 100g

Typical values at ambient temperature +20%
Tollerance +/-10%

3D
Loading
Photo
HV155-2S
_

Technical Drawing

Also available with two-phase Hall-effect 90° encoder – HV155-2S

_
_

Technical Drawing

Type Nominal voltage Length Reduction ratio Nominal torque Speed Current Input Power
No load At nominal torque No load At nominal torque
v mm Ncm rpm mA W
HV155 12 10 12 61,5 10 5 660 460 <140 620 7,4
24 24 <70 300 7,2
HV155 12 21 12 61,5 20,8 10 315 235 <140 600 7,2
24 24 <70 285 6,8
HV155 12 43 12 67 43,3 18 155 115 <140 580 7,0
24 24 <70 280 6,7
HV155 12 90 12 67 90,3 25 75 62 <140 440 5,3
24 24 <70 215 5,2